Product Description:
1.Compatible with most common low-voltage batteries (lead-acid & lithium)
2.Max charging/discharging current up to 120A
3.The typical switch time between on-grid mode andback-up mode is 10ms
4.Remote upgrade and configuration; safety-relatedfunctions integrated; easy for cooperating with BMS
5.IP65 protection to ensure the inverter can work undervarious environmental conditions
6.Easily installed in the residential site
Technical Parameters:
| | | | | | | | | | | Battery Type | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | | Nominal Battery Voltage (V) | | | | | | | | Battery Voltage Range (V) | | | | | | | | Max. Charge/Discharge Current (A) | | | | | | | | Max. Charge/Discharge Power (W) | 3000/3000 | 4600/4600 | 5000/5000 | 6000/6000 | 10000/8000 | 10000/10000 | | | | Max. Array Input Power (W) | 6300 | 9000 | 9000 | 9000 | 12000 | 15000 | | Max. DC Input Voltage (V) | 550 | 550 | 550 | 550 | 600 | 600 | | Nominal DC Input Voltage (V) | 360 | 360 | 360 | 360 | 360 | 360 | | Start-up Voltage (V) | 90 | 90 | 90 | 90 | 90 | 90 | | MPPT Voltage Range (V) | 70~540 | 70~540 | 70~540 | 70~540 | 70~540 | 70~540 | | Max Input Current per MPPT (A) | 15/15 | 15/15 | 15/15 | 15/15 | 30/22/22 | 30/22/22 | | Max Short-circuit Current per MPPT (A) | 20/20 | 20/20 | 20/20 | 20/20 | 40/30/30 | 40/30/30 | | No. of MPPT | 2 | 2 | 2 | 2 | 3 | 3 | | No. of Strings per MPPT | 1 | 1 | 1 | 1 | 2 | 2 | | | | Nominal Input Apparent Power (VA) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | | Max. Input Apparent Power (VA) | 6300 | 9000 | 9000 | 9000 | 12000 | 15000 | | Max. Input Current (A) | 29 | 41 | 41 | 41 | 40 | 50 | | | | Nominal Ouput Active Power (W) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | | Nominal Output Apparent Power (VA) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | | Max. Output Apparent Power (VA) | 3960 | 5060 | 5500 | 6600 | 8800 | 11000 | | Nominal Output Voltage (V) | 220/230/240 | 220/230/240 | 220/230/240 | 220/230/240 | 220/230/240 | 220/230/240 | | Output Voltage Range (V) | 150-300(Adjustable) | - | | Nominal Output Frequency (Hz) | 50/60 | | Output Frequency Range (Hz) | 45-65(Ajustable) | | Max. Output Current (A) | 16 | 22 | 25 | 27.2 | 40 | 50 | | Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | | THDi | <3% | <3% | <3% | <3% | <3% | <3% | | | | Nominal Output Apparent Power (VA) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | | Max. Output Apparent Power (VA) | 3960 | 5060 | 5500 | 6600 | 8800 | 11000 | | Nominal Output Voltage (V) | 230 | 230 | 230 | 230 | 230 | 230 | | Nominal Output Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | | Max. Output Current (A) | 18 | 23 | 25 | 30 | 34.8 | 43.5 | | Transfer Time (ms) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | | THDv @ Linear load | <3% @100% R Load | <3% @ 100% R Load | | | | Max. Efficiency | 97.30% | 97.30% | 97.30% | 97.30% | 98% | 98% | | Battery Discharge to AC Efficiency | 94.30% | 94.30% | 94.30% | 94.30% | 95% | 95% | | | | PV Reversed Polarity Protection | Yes | Yes | | Residual Current Monitor | Yes | Yes | | PV Over Voltage Protection | Yes | Yes | | PV Over Current Protection | Yes | Yes | | Anti-islanding Protection | Yes | Yes | | DC Surge Protection | Type III | Type II | | AC Surge Protection | Type III | Type II | | Insulation Resistor Detector | Yes | Yes | | Output Over Current Protection | Yes | Yes | | Output Short Circuit Protection | Yes | Yes | | Output Over Voltage Protection | Yes | Yes | | Generator | - | Yes | | AFCI | - | Optional | | Remote Shutdown | - | Optional | | Rapid Shutdown | - | - | | | | Operating Temperature Range (°C) | -25℃~60℃ | -25℃~60℃ (>45℃ derating) | | Relative Humidity | 0~100% | 0~100% | | Max. Operating Altitude (m) | 4000 | 4000 | | Cooling Method | Natural Cooling | Fan Cooling | | User Interface | APP+LED | LED+APP | | Communication | RS485/CAN (for BMS), RS485, USB, DRM/RS485 (for Meter), Optional: WiFi/GPRS/LAN | RS485/CAN (for BMS), RS485, USB, DRM/RS485 (for Meter), Optional: WiFi/GPRS/LAN | | Weight (kg) | 20 | 25 | 25 | 25 | 37 | 37 | | Dimension (W × H × D mm) | 515*485*175 | 420*800*240 | | Topology | Transformerless | Transformerless | | Ingress Protection Rating | IP65 | IP65 | | Mounting Method | Wall Bracket | Wall Bracket | |






Applications:
-
Multi-Source Integration:
- Combines energy from solar panels, battery storage, and the grid, allowing for flexible energy use and improved efficiency.
-
Energy Management:
- Smart energy management capabilities enable users to prioritize energy sources based on real-time conditions and individual preferences, maximizing savings and efficiency.
-
Backup Power:
- Provides reliable backup power during grid outages, ensuring essential loads remain operational.